The wire sizes given are suitable for a 15' (4.6 meter) “round trip” length. In certain installations
the wire lengths to certain component parts may exceed this. If this is the case in your
installation find the maximum current draw from the list below and use the wire sizing table
shown on the next page to identify the correct wire size. The Micro HPS draws 28 amps at 12 V
while the refrigerator or freezer is running, and 45 amps at 12 V while the air conditioning is
running. Remember, the wire length is always considered to be the total distance from the
power source to the device and back again. The table below gives the current draws which
should be considered when sizing the wire runs. The DC is rated at 12 volts and the AC at 110
volts. Multiply by .5 for 24v and 220v.
(This is a Prestart Checkout Item)
● Micro HPS (DC) - 50 amps ● Solenoid Coil (ea) - 2 amps
● Water Pump (DC) - 10 amps
● Arctic Air Fan (ea) - 2 amps
Basic Electrical Wiring
Closely follow the wiring schematic and written identifications of the wiring connections which are
included in the sleeve of this manual. In planning your wiring remember:
1. Use only 100% tinned stranded copper wire of the recommended AWG size.
2. Always use the recommended size circuit breaker on the main power line.
3. Butt splices should be crimped and sealed with heat shrink tubing.
4. When making connections to the terminal block, be sure to tighten the clamping screws firmly.
(All high-power connections should also be rechecked for tightness at regular intervals)
Wire Size
In addition to using the right type of wire, it is also important to use the correct wire size. While
this is important for both AC and DC systems, it is in high-current DC systems that installers tend
to underestimate the size of wire needed. Refer to the tables on the following pages for a
general reference when selecting a wire size as a function of length and current. The Glacier
Bay wiring diagram calls out wire size by AWG gages. AWG is used in the United States while
Metric diameter is used in the rest of the world. For convenience, an AWG - Metric conversion
table is also provided.
Page 33
Comentarios a estos manuales