MICRO-AIR Artic Air 24 Guía de instalación Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 63
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
Installation of the Trimline
TM
Spidercoil
TM
Evaporator Plates
Materials Required (conventionally insulated boxes)
Stainless steel or bronze wood screws
Materials Required (BARRIER Ultra-R
tm
Boxes)
BARRIER plate mounts (set) or 1/4" fiberglass sheet and flat-head screws
Tools Required
Marking pencil
Tape measure
Screw driver
Drill and bit
Wood blocks to position and support plate during installation
WARNING: Read and understand the next section “Running The Copper Tubing” before
mounting your plates. Make certain that you have sufficient room to properly route the tubing.
Oil traps MUST be avoided and you must leave enough room to properly clamp the expansion
valve sensing bulbs and accommodate check valves.
Refrigeration Plates and Freezer Plates
Refrigeration plates and freezer plates are identical except for the eutectic solution inside and the
corresponding temperature rating engraved on the back of the plate. The standard freezer
solution (TSS -8) is rated at -8
0
F (-22
0
C) and the refrigeration solution TSS+26 at +26
0
F (-3
0
C). These temperature ratings reflect the eutectic point (freeze/thaw temperature) of the
solution. The plates are not interchangeable and cannot be used outside their intended functions
without an extreme loss in efficiency and holdover.
Mounting Positions
The evaporator plates rely on convective circulation to absorb heat from the air in the box. They
work best when mounted high in the box on the side walls. Mounting the plates on the top
(ceiling) of the box is not generally recommended. The plates can be mounted either vertically or
horizontally so long as the thermal expansion valve is not facing down and that proper tubing
connections are maintained (see the section on “Running the Copper Tubing”). Be sure and
mount freezer plates so that no area of the box is further than 18" from a plate.
Installing Plate(s) - With Standard Foam Insulation
Position all holding plate(s) and support them in place with suitable wooden blocks. After
ensuring that all positioning is correct, use a pencil to mark the location of all eight holes in each
holding plate mounting flange. Remove the plates and pre-drill the screw holes with a suitable
size bit. Re-install the holding plate(s) using at least four (4) bronze or stainless steel screws on
#1 and #2 plates and eight (8) on #3 and #4 plates.
Page 16
Vista de pagina 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 62 63

Comentarios a estos manuales

Sin comentarios